Technical Solutions

Engineering for every need in climate, air, and safety.

We design and implement climate control, ventilation, and pressurization systems adapted to the technical characteristics of each project.

Esquema técnico de Climatización y Ventilación
Central Climate Control & Ventilation Equipment
TECHNICAL SELECTION CRITERIA

Not all spaces require the same solution.

System selection considers surface area, use, required capacity, distribution, energy efficiency, and particular project conditions.

SURFACE AREA
Dimensions and thermal volume m³
USAGE TYPE
Residential, commercial, or office
CAPACITY
Required thermal load BTU/h
DISTRIBUTION
Ducts, zoning, or cassettes
EFFICIENCY
Inverter technology and consumption
01 — COMPREHENSIVE CLIMATE CONTROL

Technology and thermal comfort.

Systems to condition everything from individual areas to entire floors with zoned control.

Sistema VRF Inverter en Sanatorio La Costa
📍 Sanatorio La Costa (Clínica / Hospital) · Sistema VRF Inverter
MAXIMUM ENERGY EFFICIENCY

VRF Systems (Variable Refrigerant Flow)

Variable refrigerant volume that automatically adapts consumption according to the real demand of each space. Ideal for healthcare and corporate facilities.

  • Independent zoning per room
  • Continuous Inverter energy savings
  • Multiple indoor units to 1 outdoor condensing unit
Sistemas Split Cassette y Piso Techo
Official Mounting Diagram · Floor-Ceiling Split
INDEPENDENT AND MODULAR UNITS

Split Systems (Wall, 360° Cassette, Floor-Ceiling)

Versatile and independent units for offices, event halls, and residences. The 360° Cassette offers uniform distribution in false ceilings without aesthetic compromise.

Application: Residential / Commercial / OfficesSplit & Cassette
CONCEALED CENTRAL CLIMATE CONTROL

Central Ducted Systems

Homogeneous airflow distribution through grilles and diffusers integrated into the architectural design. Recommended for large areas and open-plan floors.

Application: Offices / Shopping Centers / Commercial SpacesCentral Ducts
Sistemas por Ductos Centrales
Official Mounting Diagram · Ducts in False Ceiling
LARGE COMMERCIAL TONNAGE

Packaged / Rooftop Units

Self-contained high-capacity units installed outdoors for conditioning large volumes.

Reference Project:Shopping del Este
Registered Capacity:6,120,000 BTU/h
Sistema Compacto Rooftop en Shopping del Este
02 — MECHANICAL VENTILATION

Air in motion where the project demands it.

We implement mechanical air renewal, extraction, and supply solutions for spaces where natural ventilation is insufficient.

Esquema de Ventilación Mecánica y Extracción

SYSTEM FUNCTIONS

RENOVACIÓN01
Basements & Parking Areas

Elimination of carbon monoxide and accumulated gases in underground floors using centrifugal and axial fans.

EXTRACCIÓN02
Warehouses & Industrial Buildings

Fresh air injection and exhausted warm or contaminated air expulsion to maintain optimal working environmental conditions.

INYECCIÓN03
Critical & Healthcare Environments

Controlled intake of treated air with pre-filtration stages for areas requiring particulate control.

COMMON APPLICATIONS
  • Subsuelos y Estacionamientos de Edificios
  • Plantas Industriales y Logísticas
  • Cocinas Comerciales e Industriales
  • Áreas Técnicas y Depósitos
  • Sanatorios y Locales Concurridos
03 — STAIRWELL PRESSURIZATION

Protection of evacuation routes.

Positive pressure air injection systems to contribute to smoke control in emergency stairwells of high-rise buildings.

Esquema técnico de Presurización de Escaleras de Emergencia
EMERGENCY OPERATIONAL SEQUENCE

Dynamic pressure control at height

The system maintains continuous overpressure in the stairwell enclosure preventing smoke from entering when access doors are opened during evacuation.

01
DETECTION
Activation via smoke sensors
02
POSITIVE PRESSURE
Continuous clean air injection
03
SMOKE CONTROL
Prevention of smoke ingress into emergency enclosures
04
EVACUATION ROUTE
Smoke-free stairwell for occupants
APPLICATION COMPARISON

Which solution fits your project?

Guidance matrix according to project typology and scale.

SYSTEM / SOLUTIONRESIDENTIALCOMMERCIALCORPORATEINDUSTRIAL / INST.
Split (Pared / Cassette / Piso-Techo)●●○—
Sistemas VRF & Inverter●●●○
Sistemas por Ductos Centrales○●●●
Equipos Compactos Rooftop—●○●
Ventilación Mecánica & Extracción○●●●
Presurización de Escaleras●●●●
● Highly recommended○ Applicable depending on design— Uncommon

* The definitive solution is determined according to the characteristics and technical requirements of each project.

ON-SITE SYSTEM EVIDENCE

Systems in operation.

Sanatorio La Costa (Clínica / Hospital)
Asunción

Sanatorio La Costa (Clínica / Hospital)

VRF Air System (1.900.000 BTU)

Shopping 14 y Medio

Shopping 14 y Medio

Centralized Air Conditioning System (1.200.000 BTU)

Edificio San Clemente (Sta. Teresa)
Santa Teresa, Asunción

Edificio San Clemente (Sta. Teresa)

Wall-Mounted Split Air System & Stairwell Pressurization & Mechanical Ventilation / Extraction (1.800.000 BTU)

Technical Selection Criteria
  • 01.Precise thermal load calculation (BTU/h)
  • 02.Evaluation of usage typology and zoning
  • 03.Consumption optimization and Inverter technology
  • 04.Architectural integration in plenum and false ceiling
System Evaluation

Let us determine the appropriate solution for your project.

We analyze the thermal, spatial, and regulatory characteristics of your project to specify the most efficient HVAC system.

Avda. Madame Lynch c/ Rio Paraguay
Asunción, Paraguay
+595 971 138 553
info@casaclima.com.py